Archive for the ‘Maintenance’ Category

How can I use Raptor columns and the EXP Direct connect holder with stainless steel fittings?

Some customers may find themselves with this scenario. You have an HPLC instrument with existing stainless steel tubing and fittings and you are getting ready to install a Raptor column. The end of your tubing may very well look like the one shown above. Here are some questions you might have.   Can I attach […]

Need parts for your Agilent 1100? HP 1050? Restek has you covered.

As of May 31, 2015, 1100 Series HPLC systems were categorized “End of Guaranteed Support” (EGS) by Agilent. Agilent would prefer it if you purchased a new system from them, but 1100 HPLCs are dependable workhorses. Why not keep them running with instrument replacement parts from Restek? Check out our selection, easily sorted by instrument and module: […]

Leak Detector Lithium Ion Battery

Lithium ion batteries have been in the news quite a lot recently, and not all of it has been positive.  There have been numerous incidents of different products from airplanes to hoverboards to mobile phones catching fire during charging or operation.  These problems occur when there has been damage to the cells’ structure or to the […]

It May be Hot Outside, but Your Headspace Analysis Can Still Suffer from the Cold

Summer days are my favorite – hot, sunny, and full of fun. But one thing that’s really not fun is trying to track down contamination and/or carryover in your headspace-GC (HS-GC) system. I get questions about this topic pretty regularly, so I thought I would post a blog on the most common culprit for contamination […]

Looking for a Cryogenic Valve for your Shimadzu GC-MS?

I was working on a project for volatile sulfur analysis. It took so long to cool the GC oven to 30 °C, and yet the most volatile analytes were still difficult to separate. At that time, I realized that I needed a cryogenic cooling system for my Shimadzu GC-MS QP2010 plus! However, I was not as excited as […]

Think you must use RFID-tagged lamps? Think again!

The recent addition of Radio Frequency Identification tags (RFID tags) to detector lamps allows automatic reference and usage data collection to your system software. This is convenient but comes at a cost: up to 40% more for an OEM-tagged lamp compared to a Restek replacement lamp. At the time of the writing of this blog […]

Don’t Forget to Change Your GC Inlet Bottom Seal and Trim Your GC Column as Part of Your Maintenance Routine!

While doing PAH analysis for dirty samples with splitless GC I saw increased peak tailing and loss of response, so I did what anybody would do: changed my GC inlet liner.  In this case I used a Restek Premium single taper inlet liner with wool.  Unfortunately when I did my next standard analysis, not much was improved.  […]

Check out Dual Vespel® Ring Inlet Seals

Inlet seals are a critical component for ensuring a leak free seal at the base of a GC inlet.  For those of you who are using standard inlet seals on Agilent or Thermo Trace instruments, Restek also offers an alternative known as the Dual Vespel® Ring seal.  This seal features a Vespel® ring on each side […]

Do you love your pet? Then you will love our Raptor™ Biphenyl LC column.

Have you ever faced this? Your pet has a stomach problem and nothing helps except to visit the veterinarian? Most likely, your beloved dog or cat is infected with parasitic protozoans, causing a disease called coccidiosis. Help is in sight; the veterinarian will use a pharmaceutical out of the group of coccidiostats and there is […]

SDS’s for 22010, 22011, 22014 and 22015 (Indicating Oxygen & Moisture traps/filters)

Even though we are not required to include a SDS (MSDS) for most of our products (articles), we often get asked for them for our gas filters/traps (for disposal information). Included below are the SDS’s for the following Restek catalog numbers: 22010 & 22011 (Indicating Oxygen traps/filters) 22010-22011 MSDS Restek       22014 & […]