Don’t forget the end fittings when you purchase an inline gas regulator

Recently I talked to a couple of customers who ordered an inline gas regulator, but didn’t order any end fittings, so when the regulator arrived, they weren’t able to connect it to their gas line.  As a result, I decided to write this post to remind our customers that they may need to purchase end fittings when ordering an inline gas regulator.

21666_ph_so_reg

Because each of our inline regulators (catalog numbers 21666* or 22452*) has 1/4 inch FNPT (Female National Pipe Thread) ports on each end (input & output), you would need two fittings for each regulator.  Because we sell associated fittings in ten-packs, you will have spare fittings if you order just one of the following catalog numbers:

To connect to 1/4 inch copper tubing, choose 23134 if you prefer Swagelok® fittings or 21842 if you prefer Parker® fittings.

To connect to 1/8 inch copper tubing, choose 23136 if you prefer Swagelok® fittings or 21844 if you prefer Parker® fittings.

 21841_ph_so_fit

(Note:  You may also want to order some PTFE tape if needed.  ResTape PTFE Tape)

 

If you are reading this and realize you actually need a regulator with a CGA fitting (to connect to a tank/cylinder), I have a previous post which discusses these regulators (link below).

Need some help in choosing the correct gas regulator?

*The difference between 21666 and 22452 is the gauge; 21666 is designed for an outlet pressure up to 50psi and 22452 for an outlet pressure up to 100psi.  Maximum inlet pressure is 3000psi for both regulators.  Additional information is below.

.

21666 Product Name: Ultra-High-Purity Line Gas Regulator

Material: Chrome-Plated Brass

Fittings: 1/4″ female NPT ports

Outlet Gauge: 30″ – 0 to 100 psig (0-689 kPa)

Outlet Pressure: 0-50 psig (0-345 kPa)

—————-

22452 Product Name: Ultra-High-Purity Line Gas Regulator

Material: Chrome-Plated Brass

Fittings: 1/4″ female NPT ports

Outlet Gauge: 30″ – 0 to 200 psig (0-1,379 kPa)

Outlet Pressure: 0-150 psig (0-689 kPa)

 

If we do not offer a regulator which meets your specifications, we may be able to provide you with a custom product.  Please complete and submit our Custom Ultra-High Purity Gas Regulator Quote Form.

Leave a Reply


Restek Domestic Customer Service

Subject

Message

Your Full Name

Your Email

Company Name

Address

Spam Block (Please leave this blank)

all fields required

Thank you

Your message has been sent. We will be in touch shortly.

Message not sent

Sorry, your message could not be sent at this time. Please try again later, or contact Restek or your local Restek representative via phone.

www.restek.com/Contact-Us