Posts Tagged ‘QuEChERS’

Pesticide analysis for cannabis flower: method and data overview

Pesticides in cannabis has been a hot topic lately and we have been getting many requests for help with this analysis. We did work on pesticide residue testing in cannabis about 6 years ago. At that time, we were limited to testing our methods with a small amount of seized material. Recently, we have been […]

Need Help with QuEChERS: #AskRestek Twitter Q&A session

Just wanted to let everyone know we will be hosting a #AskRestek Twitter Q&A session about QuEChERS next week at 3:00 p.m. EST (12:00 noon PST) on Tuesday, May 3. QuEChERS is a great approach for sample preparation with lots of benefits. It is also very flexible which is nice but that can also make […]

Difficult QuEChERS extracts: Removing fatty acid interferences

Using the QuEChERS extraction and cleanup method for high fat commodities such as, nuts, dairy, fish, and avocado can be difficult to analyze for pesticide residues.  Using the dispersive solid phase (dSPE) cleanup sometimes is just not enough to adequately remove the fatty acid co-extractives. Check out this technical article on how to quickly yet […]

The Most Useful Pesticide Standard Ever…monitoring GC inlet “dirtiness”

I have spent most of my time over the past several years testing pesticides and there is one standard that I simply can’t live without…QuEChERS Performance Standards Kit. It is based on a really interesting article* on analyte protectants with a few compounds added. The standard has 40 compounds housed in three vials for long […]

Great Internal Standards for Pesticide Residues…SRMs too!

  In just about all of my pesticide residue work, I use a convenient multicomponent internal standard mix that contains several PCBs as well as popular internal standard compound triphenylphosphate. The mix contains the six compounds in the chromatogram below. I have been working on a method for our GC Multiresidue Pesticides Kit which has […]

QuEChERS – Where to start?

Enjoy the tip!* I am often asked for QuEChERS product recommendations. Usually the request is something like, “I need to test pesticides in _____” and that blank can be just about anything…sometimes not even food. Unless it is something I have tested before, I usually take a quick look online to determine the approximate composition […]

Which GC instrument should I use for the analysis of pesticides in herbal tea? GC-MS/MS or GCxGC-TOFMS?

You may remember a while ago I posted a blog about the analysis of herbal tea using QuEChERS and GCxGC-TOFMS.   The LECO Pegasus GCxGC-TOFMS is a great instrument for analyzing complex samples because of the comprehensive chromatographic separation achieved (two columns with different selectivities).  The GCxGC-TOFMS also excels at non-target screening of compounds.  Lucky for […]

Inject more fish extracts before GC maintenance is needed using shoot-and-dilute GC

Persistent organic pollutants (POPs) like dioxins, furans, polychlorinated biphenyls (PCBs), and polybrominated diphenyl ether (PBDEs) are lipophilic and therefore may be found in fatty matrices like fish.  In order to remove the high lipid coextractives, lengthy cleanup procedures that require multiple cleanup cartridges are often used.  I recently presented work at the Dioxin meeting where […]

Shortcut: AOAC QuEChERS protocol

Here is our checklist style protocol based on the AOAC 2007.01 QuEChERS method. The document describes producing spiked samples at 10 ppb and no spiked samples that are used to determine incurred pesticides. Commodity samples that are not spiked as also used to product matrix-matched standards. During method development we usually test more than one […]

Analyzing pesticides in herbal tea using QuEChERS and GCxGC-TOFMS of course!

Herbal tea, a non-caffeinated drink made from plants, herbs, or spices has been used throughout history for its potential medicinal benefit.   Various herbal material is mixed depending on the desired medicinal or flavor properties for the tea.   As with any plant based commodity, there is the potential for pesticide residues to remain in the final […]